      Air-Cooled vs Liquid-Cooled AI Servers: How to Future-Proof Your H200 Server Deployment

      Written by :
      Team Uvation
      | 7 minute read
      |June 13, 2025 |
      Category : Infrastructure
      Air-Cooled vs Liquid-Cooled AI Servers: How to Future-Proof Your H200 Server Deployment

      Modern artificial intelligence demands immense computing power. AI servers rely on specialized hardware like NVIDIA H100 or AMD MI300X GPUs to train complex models. This incredible power comes with a significant challenge: intense heat generation.

       

      When this heat isn’t effectively managed, servers slow down to protect themselves. This performance loss, known as thermal throttling, directly impacts AI tasks. Excess heat also reduces the lifespan of valuable hardware components over time. Traditional air cooling methods are increasingly struggling to handle this thermal load efficiently.

       

      Today’s dense AI workloads push air cooling to its limits. A single rack packed with high-performance AI servers can easily consume 30-50 kilowatts of power. Removing heat thus generated quickly and quietly becomes difficult with air alone. Hot spots can develop, hindering performance and reliability.

       

      Liquid cooling offers a powerful alternative. Instead of relying on air, it circulates coolant directly to the hottest components like CPUs and GPUs. Because liquid absorbs and transfers heat more effectively than air, this approach enables denser, more powerful server configurations within the same physical space.

       

      This creates a critical decision point for businesses deploying AI servers. Should you use familiar air-cooled systems, like the HPE XD685? Or is it time to adopt advanced liquid-cooled infrastructure? This choice significantly impacts performance, operational costs, and your ability to scale future AI projects.

       

      This guide dives into the “air-cooled vs liquid-cooled ai servers” debate. Whether you’re considering a proven air-cooled solution or exploring liquid-cooled clusters, we’ll help you make the right choice for your AI deployment.

       

      AI server cooling strategy decision matrix for H200 deployment

       

      1. Air-Cooled AI Servers: Proven but Limited

       

      1. How It Works

       

      Air-cooled servers rely on airflow to manage heat. Fans pull cool air from the data center environment. This air flows over heatsinks attached to hot components like CPUs and GPUs. The heatsinks absorb heat from the hardware. The warm air is then exhausted out of the server rack. This cycle repeats continuously to maintain safe temperatures.

       

      2. HPE XD685 Spotlight

       

      The HPE XD685 is a leading example of modern air-cooled AI infrastructure:

       

      • Specs: Fits 8 high-power GPUs in a compact 2U chassis. Supports GPUs drawing over 350W each.
      • Ideal For: Mid-density AI deployments (e.g., inferencing, moderate-scale training). Easily integrates into standard data centers without facility upgrades.

       

      3. Pros of Air-Cooled AI Servers

       

      • Lower Upfront Cost:
        No need for chillers, pumps, or coolant pipes. Hardware costs are lower than liquid-cooled alternatives.
      • Simpler Maintenance:
        IT teams already understand fan and heatsink replacements. No specialized coolant handling or leak protocols.
      • Compatibility:
        Works in any standard data center with adequate airflow. No facility retrofits are required.

       

      4. Cons of Air-Cooled AI Servers

       

      • Thermal Ceiling (~40kW/Rack):
        Air cannot efficiently remove heat beyond ~40kW per rack. High-density GPU deployments risk overheating.
      • Energy Inefficiency:
        Server fans consume 15–30% of total system power. This increases electricity costs significantly on a scale.
      • Noise and Hot Spots:
        Fans generate loud noise (85dB+). Uneven airflow creates hot spots, forcing GPUs to throttle performance.

       

      5. Where Air Cooling Fits in the “Air-Cooled vs Liquid-Cooled AI Servers” Debate

       

      Air-cooled systems like the HPE XD685 excel in smaller-scale or budget-conscious AI deployments. They offer plug-and-play simplicity for workloads under 40kW/rack. However, they hit hard limits in power density, energy efficiency, and scalability. For enterprises planning intense AI training or high-density racks, these constraints make liquid cooling essential.

       

      Air vs liquid cooling rack density comparison visual

       

      2. Liquid-Cooled AI Servers: The High-Density Answer

       

      1. How It Works: Two Key Methods

       

      Liquid cooling bypasses air to remove heat directly from hardware. There are two primary approaches:

       

      • Direct-to-Chip (D2C):
        Metal cold plates sit directly on hot components like CPUs and GPUs. Coolant flows through microchannels in these plates, absorbing heat. The warm liquid travels to a heat exchanger, cools, and recirculates.
      • Immersion Cooling:
        Entire servers are submerged in a non-conductive dielectric fluid. The fluid absorbs heat as it flows over components. Warm fluid is pumped out and cooled externally before returning.

       

      2. Pros of Liquid-Cooled AI Servers

       

      • Extreme Density Support (100kW+/rack):
        Liquid handles heat 50x better than air. This allows racks packed with GPUs to safely exceed 100kW, far beyond air cooling’s ~40kW limit.
      • Major Energy Savings (30–50% less cooling energy):
        Liquid systems use efficient pumps instead of power-hungry fans. This slashes data center cooling costs and power usage effectiveness (PUE).
      • Performance Boost & Hardware Protection:
        Components run 20–30°C cooler. This prevents thermal throttling, enabling GPUs to sustain peak clock speeds during long AI training jobs. Cooler operation also extends hardware lifespan.

       

      3. Cons of Liquid-Cooled AI Servers

       

      • High Upfront Cost (CapEx):
        Requires coolant distribution units (CDUs), piping, leak sensors, and fluid. Installation costs are significantly higher than air-cooled setups.
      • Facility Demands:
        Often needs raised floors for plumbing, water lines, and containment areas. Retrofitting existing data centers can be complex.
      • Maintenance Complexity:
        Requires handling coolant (filtering, replenishing), inspecting seals, and specialized technician training. Leak risks, though low, demand strict protocols.

       

      4. Liquid Cooling’s Role in the “Air-Cooled vs Liquid-Cooled AI Servers” Debate

       

      Liquid cooling isn’t just an upgrade—it’s essential for high-intensity AI workloads. When deploying racks beyond 40kW or using next-gen 700W+ GPUs, liquid is the only viable option. While its startup costs and complexity are higher, the long-term gains in density, efficiency, and performance make it valuable for scaling AI. For enterprises running large language models or full-scale training clusters, liquid cooling is not optional. It’s strategic.

       

       server cooling strategy decision matrix for H200 deployment

       

      4. Head-to-Head Comparison

       

      Criterion Air-Cooled (e.g., HPE XD685) Liquid-Cooled Decision Trigger
      Thermal Efficiency Max ~40kW/rack 100kW+/rack >40kW rack? Choose liquid.
      Upfront Cost (CapEx) Lower hardware cost (No extra infrastructure) Higher (CDUs, piping, coolant, sensors) Tight budget? Start with air.
      Operational Cost (OpEx) High fan power (15–30% server energy) 30–50% lower cooling energy Scaling long-term? Liquid saves $/kW.
      GPU Density per Server Moderate: 4–8 GPUs (e.g., HPE XD685) Extreme: 8–16+ GPUs Maximizing rack space? Liquid wins.
      Performance Stability Thermal throttling risk at >350W/GPU Sustained peak clocks (20°C+ cooler GPUs) Running 24/7 LLMs? Liquid prevents slowdowns.
      Facility Impact Minimal: Fits standard data centers Needs plumbing, containment, water sources Retrofitting? Air avoids construction.
      Noise Levels Loud (85–95 dB) – hearing protection needed Near-silent pumps (45–55 dB) Noise-sensitive? Liquid is office-friendly.
      Sustainability Higher PUE (1.5–1.8) PUE 1.03–1.1 (30%+ carbon reduction) Meeting ESG goals? Liquid is greener.

       

      Criteria Air-Cooled (HPE XD685) Liquid
      Max Rack Density ≤40kW 100kW+
      Deployment Cost Lower Higher (cooling infra)
      OpEx (Energy) Higher PUE (1.5–1.8) Lower PUE (1.03–1.1)
      Hardware Longevity Heat reduces component life Cooler operation extends life
      Facility Impact Minimal retrofits Major plumbing/space changes

       

      5. When to Choose Which?

       

      • Choose Air-Cooling (HPE XD685) if:
        • Deploying in existing air-optimized data centers.
        • AI workloads are bursty/moderate (<40kW/rack).
        • Budget constraints prioritize CapEx over OpEx. .
      • Choose Liquid-Cooling if:
        • Planning 24/7 high-intensity training (LLMs, generative AI).
        • Targeting >40kW/rack or next-gen GPUs (e.g., Blackwell).
        • Sustainability/energy efficiency is critical (ESG goals).

       

      6. Key Considerations for AI Deployments

       

      • Thermal Management: Liquid enables 10-15% higher GPU clocks
      • TCO Analysis: Liquid’s higher CapEx offsets by 20-40% OpEx savings over 3-5 years
      • Hybrid Approach: Use air for CPU/memory + liquid for GPUs
      • Future-Proofing: Liquid cooling essential for 500W+ GPUs

       

      7. The Road Ahead

       

      • Vendor Trends: HPE’s liquid-cooled ProLiant DL380, Dell’s D2C solutions.
      • Sustainability: Liquid cuts carbon footprint by 30%+
      • Emerging Tech: Single-phase vs. two-phase immersion cooling.

       

      8. Conclusion: Match Cooling to Your AI Ambition

       

      • Air-Cooled (HPE XD685): Best for today’s pragmatic, mid-scale deployments.
      • Liquid-Cooled: Essential for tomorrow’s high-density, sustainable AI.
        Final Tip: Audit GPU utilization and facility constraints first!

       